Inverted Bucket BearTrap®

Bell & Gossett : Steam Specialties : Traps

Bucket Traps

For efficient condensate drainage of industrial process and HVAC equipment.

Inverted bucket traps rely on the density difference between steam and water to drain condensate as it forms. An inverted bucket floats in condensate that surrounds the bucket. As the bucket moves up and down in the condensate, a linkage connected to the bucket closes or opens a discharge valve trapping the condensate or allowing it to escape. Maximum system efficiency results from steam space being kept free of condensate.

Operation of Bucket Traps:

 

The trap body must be manually primed at initial start-up. (Under low load or superheat conditions, the trap may also need to be primed.) Under operation, the trap body will remain full of condensate.

An inverted bucket floats in the condensate that surrounds the bucket itself. As the bucket moves up and down in the condensate, a linkage connected to the bucket closes or opens a discharge valve located at the top of the trap, trapping the condensate or allowing it to escape.

During start-up, air is vented through a bleed hole in the top of the bucket into the return line. When air or steam flows into the trap, it enters the underside of the bucket and collects in the top of the bucket. The contained air and steam cause the bucket to become buoyant and rise in the condensate causing the lever mechanism to close the discharge valve into its seat.

The bucket loses its buoyancy as the enclosed steam condenses due to radiation losses and steam escaping through the bucket vent hole. When this happens, the weight of the bucket will cause it to fall and pull the valve off its seat, and the cycle repeats.

An optional thermal vent installed in the bucket allows faster air venting during start-up.

Characteristics of Bucket Traps:

  • Completely drains condensate at saturation temperature.
  • Open bucket design will tolerate moderate water hammer.
  • Normal failure mode is open.
  • Sediment and dirt are kept in suspension until discharged with condensate.
  • Only two moving parts, lever assembly and bucket, leads to reliable operation.
  • Does not sub-cool condensate.
  • Marginal air handling during start-up.
  • Cycles fully open or closed, which can create noise.
  • May lose prime during light loads and blow live steam.
  • Requires manual priming to provide water seal.
  • Does not withstand freezing temperatures.

Primary Applications for Bucket Traps:

Best for stable, steady load and pressure conditions.

  • Process main drip traps for continuous operations.
  • Where condensate is lifted or drains into wet return line.
  • Heat exchangers without a modulating steam regulator.
  • High pressure applications.
  • Drum type roller dryers.
  • Steam separators.
  • Laundry equipment.
  • Siphon or tilting kettles.

Features and Benefits

  • Stainless steel internal components withstand corrosion.
  • Cast iron bodies for long, dependable life.
  • Wide range of seat pressures available – up to 250 psig to fit a wide variety of applications.
  • B0, B1, B2, B3, and B4 models:
    • Removable covers for easy in-line service.
    • Optional built-in strainer reduces number of piping connections.
    • Optional built-in thermal vent for faster heating. (B1, B2, B3 and B4 models only).

Guidelines

    General Selection Tools:

    • ESP-PLUS for B&G Centrifugal Pumps, Booster Pumps, Pump Accessories, and Air Separator
    • ESP-PARTS for replacement parts selection
    • ESP-TANKS for replacement parts selection
    • CAD Drawings for 2D and 3D dimensional drawings in many formats

    Heat Exchanger Product Selection

    Steam + Water Pressure Reducing Values

    Sizing Tools:

    Report Bugs/Request Enhancements
    Please email the following address to report issues and request enhancements: ebusiness.support@xyleminc.com

    Consult your local Bell & Gossett Representative for additional assistance.

    Xylem Water Systems Australia Pty. Ltd
    Unit 3/1 Federation Way,
    Chifley Business Park
    3194 Mentone Victoria
    Australia
    Tel. +61 3-95517333
    Fax +61 3-95510321
    Australia Distributors

    Queensland
    Brown Brothers Engineers
    50 Nestor Drive
    Meadowbrook QLD 4131
    Phone:07 3200 6488
    Fax:07 3200 3822
    New South Wales and Australian Capital Territory
    Brown Brothers Engineers
    211-215 Walters Rd
    Arndell Park NSW 2148
    Phone:02 9671 3666
    Fax:02 9671 3644
    Victoria and Tasmania
    Brown Brothers Engineers
    8 Damien Court
    Dandenong Vic 3175
    Phone:03 9793 9999
    Fax:03 9793 0022
    Western Australia
    Advanced Pump Technologies
    72 May Holman Drive
    Bassendean WA 6054
    Ph: 08 6143 1000
    Fx: 08 6143 1009
    South Australia and Northern Territory
    WBS Pumps
    6A Lasalle Street
    Dudley Park SA 5008
    Phone:08 8344 9927
    Fax:08 8344 9925
    New Zealand Distributors
    Christchurch (head office)
    Brown Brothers Engineers
    197 Durham Street
    Christchurch 8011
    New Zealand
    Phone: 3 365 0279
    Fax: 3 366 6616
    Dunedin
    Brown Brothers Engineers
    10 Timaru Street
    Dunedin 9012
    New Zeland
    Phone: 3 456 2562
    Fax: 3 456 2564
    Timaru 
    Brown Brothers Engineers
    Unit 6/39 North Street
    Timaru 7910
    New Zealand
    Phone: 3 683 1686
    Fax: 3 683 1687
    Auckland
    Brown Brothers Engineers
    124A Hugo Johnston Drive
    Penrose, Auckland 1061
    New Zealand
    Phone: 9 525 8282
    Fax: 9 525 8284
    Hamilton
    Brown Brothers Engineers
    97C Norton Road
    Frankton, Hamilton 3204
    New Zeland
    Phone: 7 847 5280
    Fax: 7 847 1580
    Wellington
    Brown Brothers Engineers
    9 Aglionby Street
    Lower Hutt, Wellington 5010
    New Zealand
    Phone: 4 570 1500
    Fax: 4 570 1499